OMRON S8VK-G48024
Power rating | 480 W |
---|---|
Efficiency | 89% TYP. (at 100 VAC input) 92% TYP. (at 200 VAC input) |
Rated input voltage | 100 to 240 VAC |
Allowable input voltage variable range | 85 to 264 VAC 90 to 350 VDC |
Note at DC input | The following safety standards apply to a DC input: UL 60950-1, cUR (CSA C22.2 No. 60950-1), EN 50178, EN 60950-1, and Lloyd’s. For a DC input, safety is ensured by an external fuse. Please select for external fuse 12 A 350 VDC or more. |
Frequency | 50/60 Hz (47 to 450 Hz) |
Rated input curren | 5.5 A TYP. (at 100 VAC input) 2.7 A TYP. (at 200 VAC input) |
Power factor | 0.9 min. |
Leakage current | 0.5 mA max. (at 100 VAC input) 1.0 mA max. (at 200 VAC input) |
Inrush current | 16 A TYP. (at 100 VAC input (For cold start at 25 ℃)) 32 A TYP. (at 200 VAC input (For cold start at 25 ℃)) |
Output voltage | 24 VDC |
Output voltage variable range | -10 to +15% (With V. ADJ) |
Ripple | 290 mV(p-p) max. (at 20 MHz (Typical)) |
Static input variation influence | 0.4% max. |
Static load variation influence | 0.8% max. at rated output voltage and the rated output current, maximum of the fluctuation of the output voltage when changing input voltage slowly at the reach of the permission input voltage |
Ambient temperature variation influence | 0.05 %/℃ max. |
Rated output current | 20 A /24 A (Peak current) |
Start up time | 500 ms TYP. (at 100 VAC input) 300 ms TYP. (at 200 VAC input) |
Hold time | 40 ms TYP. (at 100 VAC input) 50 ms TYP. (at 200 VAC input) |
Overload protection | 121% min. of the rated output current, Automatic reset |
Overvoltage protection | Operated at 130% min. of the rated output voltage, Shut-off Resetting: Reset the power by turning it back (OFF time: at least 3 min) |
Parallel operation | Yes (Up to 2 Power Supplies) |
Series operation | Yes (Up to 2 Power Supplies with external diode) |
Dielectric strength | Between all inputs and all outputs: 3 kVAC for 1 min (Cut-off current: 20 mA) Between all inputs and PE terminals: 2 kVAC for 1 min (Cut-off current: 20 mA) Between all outputs and PE terminals: 1 kVAC for 1 min (Cut-off current: 20 mA) |
Insulation resistance | Between all outputs and all inputs/ PE terminals: 100 MΩ min. (at 500 VDC) |
Vibration resistance | 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours |
Shock resistance | 150 m/s**2, in each 6 directions 3 times |
Output indicator | Yes (color: green, lighting from 80 to 90% or more of rated voltage) |
Construction | Covered type |
Structure | Terminal blocks |
Terminal type | Rod terminals |
Weight (Main) | Approx. 1500 g |
XEM CATALOG SẢN PHẨM TẠI ĐÂY