Shape/Structure |
Enclosed Limit switches |
Service life |
General type |
Actuator |
Panel mount roller plunger |
Frequency |
50/60 Hz |
Contact form |
SPDT |
Load |
General load |
Ratings (AC): Non-Inductive load |
Rated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 480 VAC / Resistive load: 2 A(NC) 2 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO) |
Ratings (AC): Inductive load |
Rated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 2.5 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 1.5 A(NO) |
Ratings (DC): Non-Inductive load |
Rated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.4 A(NC) 0.4 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO) |
Ratings (DC): Inductive load |
Rated voltage: 8 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Inductive load: 1.5 A(NC) 1.5 A(NO) / Motor load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.05 A(NC) 0.05 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.03 A(NC) 0.03 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO) |
Inrush current |
NC: 15 A
NO: 15 A |
Protective circuit |
Classification of protection against electric shock: Class II (Grounding not required with double) insulation
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269) |
Ambient temperature |
Operating: -10 to 80 ℃
(no icing) |
Ambient humidity |
Operating: 35 to 95% RH
(no condensation) |
Permissible operating frequency (Mechanically) |
120 operations / 1 minute max. |
Permissible operating frequency (Electrically) |
30 operations / 1 minute max. |
Contact resistance (Initial value) |
15 mΩ max. |
Insulation resistance |
100 MΩ min.
(at 500 VDC) |
Dielectric strength |
Between each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 2,000 VAC 50/60 Hz for 1 min |
Impulse withstand voltage |
Between each terminal and non-live-metallic part: 2.5 kV |
Durability (Mechanically) |
10,000,000 operations min.
(Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH) |
Durability (Electrically) |
500,000 operations min.
(Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH) |
Vibration resistance (Malfunction) |
10 to 55 Hz, 1.5-mm double amplitude |
Shock resistance (Destruction) |
1000 m/s**2 max. |
Shock resistance (Malfunction) |
300 m/s**2 max. |
Pollution degree |
3 (EN60947-5-1) |
Degree of protection |
IP67 |
XEM CATALOG SẢN PHẨM TẠI ĐÂY